GMS1600 Goniophotometric system is an automatic goniophotometric measurement system for measuring photometric parameters of luminaires, such as LED road lighting fixture, room lighting fixture and projecting lighting fixture.
Measure:
Electronic parameters, spatial intensity distribution curve, spatial iso-intensity curve, iso-illuminance distribution curve, luminance limitation curve, luminaire efficiency, glare grade, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor
Features:
  • To set and control the process by computer
  • Special laser cross aim device makes the installation of luminaire
  • Independent rotating table with double axes, reaching C-γ and B-β testing coordinates
  • Meet the requirements of IEC·GB standards
  • Measured data match with international standard form (IES) and can be applied for lighting design by other lighting design software
Specifications:
  • Testing optical distance: 5.0m ~ 12.0m
  • Principal axis goniometer resolution: 0.001°
  • Angle accuracy: 0.1°
  • Luminaire can be rotated by -180~180° along with horizontal axis
  • Luminaire can be rotated by -180~180° along with vertical axis
  • Electric meter accuracy: 0.5
  • Max dimension of luminaire: L1.3m*0.8m / L1.4m*0.78m
  • Max weight of luminaire: 50kg